The spreader end cap incorporates two shroud wire slots to give a tight grip on either 2.5 or 3mm wire. The sizes are identified on the front face of the end cap (See diagram above).
The end cap can be rotated so that the shroud can be positioned at either the forward or aft position of the spreader end (see diagram above).
To attach the shroud, slacken the end screw, rotate the end clamp if necessary, then insert the shroud and tighten the screw firmly.
Adjust spreader length by extending or retracting the spreader end from the spreader. Fix you required position with a clevis pin and split ring (fitted with the split ring underneath.
The position is usually described by the number of adjustment holes visible (e.g. In the diagram above there are 1 ½ holes visible).